9.2.1.2 短路電流峰值iP2
iP2=kI揔2 (26)
式中,系數(shù)k與電網(wǎng)結(jié)構(gòu)有關(guān),按第9.1.1.2或第9.1.3.2條計算,其值可采用 三相短路時計算出的k值。
9.2.2 二相接地短路
9.2.2.1 短路電流初始值I〃K2E和I〃KE 2E
圖2c中
![](http://192.168.1.17:8000/UploadFiles/UploadFiles/200932483631893.jpg)
![](http://192.168.1.17:8000/UploadFiles/UploadFiles/200932483717731.jpg)
圖2c中,流入大地或地線中的電流IKE2E,按下式計算:
上一頁 [1] [2] [3] [4] [5] [6] [7] [8] [9] [10] [11] [12] [13] [14] [15] [16] [17] [18] [19] [20] [21] [22] [23] [24] [25] [26] [27] [28] [29] [30] [31] [32] [33] [34] [35] [36] [37] [38] [39] [40] [41] [42] [43] [44] [45] [46] [47] [48] [49] [50] [51] [52] [53] [54] [55] [56] [57] [58] [59] [60] [61] 下一頁 |